IEC 61850-3 9G-port Full Gigabit managed Ethernet switch PT-G7509 Series 상세보기



   
제품분류  IEC 61850-3 9G-port Full Gigabit managed Ethernet switch / MOXA   
모델명  PT-G7509 Series
특징  IEC 61850-3 9G-port Full Gigabit managed Ethernet switch
판매가격   전화문의(02-703-0033)
적 립 금    0 점
 죄송합니다.
이 상품은 현재
출시예정 상태 입니다.
전화로 문의해 주시기 바랍니다.
 
  
 관련제품
구매 상품명 수량 단가

 제품설명
 
[제품의 사진과 설명은 실제와 다를수 있으며 제조사의 사정에 따라 변경될수 있습니다.]

Features and Benefits    

  • Command line interface (CLI) for quickly configuring major managed functions
  • IPv6 Ready logo awarded (IPv6 Logo Committee certified)
  • Software-based IEEE 1588v2 PTP (Precision Time Protocol) for precise time synchronization of networks
  • VLAN Unaware: Supports priority-tagged frames to be received by specific devices
  • DHCP Option 82 for IP address assignment with different policies
  • EtherNet/IP and Modbus/TCP industrial Ethernet protocols supported
  • Turbo Ring and Turbo Chain (recovery time < 50 ms @ 250 switches), RSTP/STP, and MSTP for network redundancy
  • IGMP snooping and GMRP for filtering multicast traffic from industrial Ethernet protocols
  • IEEE 802.3ad, LACP for optimum bandwidth utilization
  • Bandwidth management prevents unpredictable network status 
  • Automatic warning by exception through email, relay output
  • RMON for efficient network monitoring and proactive capability
  • Automatic recovery of connected device’s IP addresses
  • Line-swap fast recovery
  • Configurable by Web browser, Telnet/Serial console, CLI, Windows utility, and ABC-01 automatic backup configurator 

Cyber-security Features

  • User passwords with multiple levels of security protect against unauthorized configuration
  • SSH/HTTPS is used to encrypt passwords and data
  • Lock switch ports with 802.1X port-based network access control so that only authorized clients can access the port
  • Disable one or more ports to block network traffic
  • 802.1Q VLAN allows you to logically partition traffic transmitted between selected switch ports
  • Secure switch ports so that only specific devices and/or MAC addresses can access the ports
  • Radius/TACACS+ allows you to manage passwords from a central location
  • SNMPv3 provides encrypted authentication and access security

Introduction

The PowerTrans PT-G7509 is equipped with 9 combo Gigabit Ethernet ports, making it ideal for upgrading an existing network to Gigabit speeds and building a new full Gigabit backbone. The PT-G7509 is designed to meet the demands of power substation automation systems (IEC 61850-3, IEEE 1613). Gigabit transmission increases bandwidth to provide higher performance and transfer large amounts of video, voice, and data across a network quickly. The redundant Ethernet Turbo Ring, Turbo Chain, and RSTP/STP/MSTP (IEEE 802.1w/D/s) functions increase system reliability and the availability of your network backbone. The choice of either front or rear wiring makes the PT-G7509 suitable for different types of application.

• Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Protocols IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/ Client, BootP, TFTP, SNTP, SMTP, RARP, LACP, RMON, HTTP, HTTPS, Telnet, Syslog, DHCP Option 66/67/82, SSH, LLDP, IEEE 1588v2 PTP, EtherNet/IP, Modbus/TCP, SNMP Inform, NTP Server/Client
MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control IEEE 802.3x flow control, back pressure flow control
• Switch Properties
Priority Queues 4
Max. Number of Available VLANs 64
VLAN ID Range VID 1 to 4094
IGMP Groups 256
• Interface
RJ45 Ports 10/100/1000BaseT(X) auto negotiation speed
Fiber Ports 100/1000BaseSFP slot
Console Port RS-232 (RJ45)
System LED Indicators STAT, PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL
Mode LED Indicators LNK/ACT, FDX/HDX, RING/CHAIN PORT, COUPLER PORT, SPEED
Alarm Contact 1 relay output with current carrying capacity of 3 A @ 30 VDC or 3 A @ 240 VAC
• Power Requirements
Input Voltage • 24 VDC (18 to 36 V)
• 48 VDC (36 to 72 V)
• 110/220 VDC/VAC (88 to 300 VDC, 85 to 264 VAC)
Input Current (all ports are equipped with fiber)
• Max. 1.17 A @ 24 VDC
• Max. 0.59 A @ 48 VDC 
• Max. 0.27/0.16 A @ 110/220 VDC
• Max. 0.61/0.35 A @ 110/220 VAC
Overload Current Protection Present
Connection 10-pin terminal block
Reverse Polarity Protection Present
• Physical Characteristics
Housing IP30 protection
Dimensions 440 x 44 x 254 mm (17.32 x 1.73 x 10.00 in)
Weight 3300 g
Installation 19’’ rack mounting
• Environmental Limits
Operating Temperature -40 to 85°C (-40 to 185°F), cold start requires min. of 100 VAC at -40°C
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
• Standards and Certifications
Safety UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1
EMI FCC Part 15 Subpart B Class A, EN 55022 Class A
Power Automation IEC 61850-3, IEEE 1613
Note Please check Moxa’s website for the most up-to-date certification status.

  Model No. Description
PT-G7509-F-HV IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on front panel, 1 isolated power supply (88-300 VDC or 85-264 VAC), -40 to 85°C operating temperature
PT-G7509-R-HV IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on rear panel, 1 isolated power supply (88-300 VDC or 85-264 VAC), -40 to 85°C operating temperature
PT-G7509-F-HV-HV IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on front panel, 2 isolated power supplies (88-300 VDC or 85-264 VAC), -40 to 85°C operating temperature
PT-G7509-R-HV-HV IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on rear panel, 2 isolated power supplies (88-300 VDC or 85-264 VAC), -40 to 85°C operating temperature
PT-G7509-F-24 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on front panel, 1 isolated power supply (24 VDC), -40 to 85°C operating temperature
PT-G7509-R-24 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on rear panel, 1 isolated power supply (24 VDC), -40 to 85°C operating temperature
PT-G7509-F-24-24 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on front panel, 2 isolated power supplies (24 VDC), -40 to 85°C operating temperature
PT-G7509-R-24-24 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on rear panel, 2 isolated power supplies (24 VDC), -40 to 85°C operating temperature
PT-G7509-F-24-HV IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on front panel, 2 isolated power supplies (24 VDC and 88-300 VDC or 85-264 VAC), -40 to 85°C operating temperature
PT-G7509-R-24-HV IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on rear panel, 2 isolated power supplies (24 VDC and 88-300 VDC or 85-264 VAC), -40 to 85°C operating temperature
PT-G7509-F-48 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on front panel, 1 isolated power supply (48 VDC), -40 to 85°C operating temperature
PT-G7509-R-48 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on rear panel, 1 isolated power supply (48 VDC), -40 to 85?C operating
PT-G7509-F-48-48 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on front panel, 2 isolated power supplies (48 VDC), -40 to 85°C operating temperature
PT-G7509-R-48-48 IEC 61850-3 Full Gigabit Managed Rackmount Ethernet Switch with 9 combo 10/100/1000BaseT(X) or 100/1000BaseSFP slots for adding SFP-1FE/1G series fast/Gigabit Ethernet modules, cabling on rear panel, 2 isolated power supplies (48 VDC), -40 to 85°C operating temperature

 

Compatible Modules

 SFP-1G Series
  Model No. Description
SFP-1G10ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature
SFP-1G10ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature
SFP-1G10BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature
SFP-1G10BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 10 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature
SFP-1G20ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature
SFP-1G20ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature
SFP-1G20BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature
SFP-1G20BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 20 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature
SFP-1G40ALC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1310 nm, RX 1550 nm, 0 to 60°C operating temperature
SFP-1G40ALC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1310 nm, RX 1550 nm, -40 to 85°C operating temperature
SFP-1G40BLC WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1550 nm, RX 1310 nm, 0 to 60°C operating temperature
SFP-1G40BLC-T WDM-type (BiDi) SFP module with 1 1000BaseSFP port with LC connector for 40 km transmission; TX 1550 nm, RX 1310 nm, -40 to 85°C operating temperature
SFP-1GEZXLC SFP module with 1 1000BaseEZX port with LC connector for 110 km transmission, 0 to 60°C operating temperature
SFP-1GLHLC SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, 0 to 60°C operating temperature
SFP-1GLHLC-T SFP module with 1 1000BaseLH port with LC connector for 30 km transmission, -40 to 85°C operating temperature
SFP-1GLHXLC SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, 0 to 60°C operating temperature
SFP-1GLHXLC-T SFP module with 1 1000BaseLHX port with LC connector for 40 km transmission, -40 to 85°C operating temperature
SFP-1GLSXLC SFP module with 1 1000BaseLSX port with LC connector for 2 km transmission, 0 to 60°C operating temperature
SFP-1GLSXLC-T SFP module with 1 1000BaseLSX port with LC connector for 2 km transmission, -40 to 85°C operating temperature
SFP-1GLXLC SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, 0 to 60°C operating temperature
SFP-1GLXLC-T SFP module with 1 1000BaseLX port with LC connector for 10 km transmission, -40 to 85°C operating temperature
SFP-1GSXLC SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, 0 to 60°C operating temperature
SFP-1GSXLC-T SFP module with 1 1000BaseSX port with LC connector for 0.5 km transmission, -20 to 75°C operating temperature
SFP-1GZXLC SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, 0 to 60°C operating temperature
SFP-1GZXLC-T SFP module with 1 1000BaseZX port with LC connector for 80 km transmission, -40 to 85°C operating temperature
 SFP-1FE Series
  Model No. Description
SFP-1FELLC-T SFP module with 100Base single-mode with LC connector for 80 km transmission, -40 to 85°C operating temperature
SFP-1FEMLC-T SFP module with 100Base multi-mode with LC connector for 4 km transmission, -40 to 85°C operating temperature
SFP-1FESLC-T SFP module with 100Base single-mode with LC connector for 40 km transmission, -40 to 85°C operating temperature
 제품 배송 정보
- 배송방법 : 택배(CJ택배), 경동화물, 퀵서비스, 기타 매장수령
.................(당일 16:30분(토요일 13시) 이전 결재 완료된 주문건까지 당일 출고)
- 배송예정일 : 택배/경동화물 --> 발송후 1일~ 2일 이내(휴일제외)
.................... 퀵서비스 -> 당일 처리 (운송비는 구매자 부담)
....................(지방 중소도시 경우 1일, 도서/산간지역의 경우 2~3일 정도 추가소요됩니다. )
.................... ※명절기간 및 연말,연시에는 택배물량 증가로 위기간에서 추가로 1~2일정도 더 소요될수 있습니다.
- 배송지역 : 전국(일부 도서,산간지역 제외)
- 택배비용
................기본 택배 : CJ택배 선불/착불 3,000원 부터(박스의 크기에 따라 추가될 수 있습니다.)
................제주및 도서산간 : 지역에 따라 별도의 도선료가 추가될수 있으며, 박스의 크기에 따라 요금이 추가될 수 있습니다.
................경동화물 착불 4,000원 부터(박스의 크기에 따라 추가될 수 있습니다.)
- 택배 업체 직원으로 부터 상품 인계시 포장상태 및 제품 이상 유무(수량)를 반드시 확인 하시고
..문제 발생시 곧바로 연락(02-703-0033) 주시기 바랍니다.
 제품 A/S, 반품,환불 정보
A/S 안내 (tel.02-703-0033 시스라인)
- 상품별로 별도의 표기가 없는 경우 구입일로부터 1년이며, 운송비는 구매후 15일까지 당사가 부담합니다(택배비용에 한함).
  15일 이후는 구매자 부담입니다.

초기불량의 경우 :
- 초기불량으로 판명될 경우 구입일로부터 7일이내 CJ택배 착불로 발송 해주시면 제품 확인후 교환/반품 처리 해드립니다.
  (7일 이후부터는 고객님 부담)

변심 및 잘못구매로 인한 반품
- 왕복운송료 6,000원을 박스 동봉 후 CJ택배로 착불발송 바랍니다.(반품사유 동봉)

교환 및 반품이 가능한 경우:
- 상품을 공급 받으신 날로부터 7일이내
- 공급받으신 상품 및 용역의 내용이 표시, 광고 내용과 다르거나 다르게 이행된 경우에는 공급받은
...날로부터 3월이내, 그 사실을 알게 된 날 또는 알 수 있었던 날로부터 30일이내

교환 및 반품이 불가능한 경우 :
- 고객님의 책임 있는 사유로 상품등이 멸실 또는 훼손된 경우
...단 상품의 내용을 확인하기 위하여 포장 등을 훼손한 경우는 제외
- 포장을 개봉하였거나 포장이 훼손되어 상품가치가 현저히 상실된 경우
- 고객님의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우
- 시간의 경과에 의하여 재판매가 곤란할 정도로 상품등의 가치가 현저히 감소한 경우
  회사소개 |  쇼핑안내  |  이용약관  |  개인정보취급방침 |  운영자메일  |  입금계좌안내




EXXDAS-M040
UVT-30
NT-1100 / SC타입 멀티모드